IndustrialDehumidifierSCA 2000
When commercial spaces are less than 7,000 square feet, the SCA2000 controls outdoor heat and provides excellent humidity control. Targeted or “spot cooling” on problem areas or equipment is another application for this unit.
Hot, humid outside air is cooled to the 40 degree Fahrenheit range, providing both cold and dry air to the project. Cold air absorbs both heat and moisture, providing more comfort and lower humidity to workers and sensitive equipment. Clothes and skin stays dry even when space temperature is only cooled to 80 degree range. This provides a great sense of comfort for workers and utilizes less energy that cooling to the usual 70 degree range with standard air conditioners.
If space and portability are critical, the Subcooled Air 2000 is at home in high-rise construction projects, as well as the tight space constraints found in shipyards, refineries and many industrial settings.
Summer heat and humidity can cause seasonal enviromental issues to manufacturing, food preparation and product storage. An infusion of fully condidtioned outside air or return air can alleviate these problems.Clumping powders and half-dry product are no longer an issue when cold, dry Subcooled Air is added to the normal air stream. Subcooled Air equipment provides better drying of hot, humid air than desiccant dehumidifiers and uses less than half of the energy to do the job. There is also the added benefit of cooling that desiccants can’t provide.
The Subcooled 2000 controls outdoor heat and provides excellent humidity control.
Specifications
Subcooled Air 2000: 2,000cfm | Portable Industrial Mechanical Dehumidifier |
---|---|
Dimensions: | 34″ W x 72″ L x 80″ HH |
Weight: | 1900 pounds |
Main Disconnect: | 40 amps |
Power Supply: | 460 Volt, 60 Hz, 3 phase |
Full Load Amerage: | 35 amps @ 460 volts |
Minimum Circuit Ampacity: | 42.1 amps; #6 AWG minimum cable |
Maximum Overcurrent Protection: | 69.0 amps |
Generator Requirements: | 50KW, 480 volt |
Supply Air Blower: 2,000 cfm @ 1.0″ | leaving static pressure; 1,500 cfm @ 3.0″ leaving static pressure |
---|---|
Duct Connection: | 1 -12” diameter duct |
Filter Size: | 2 – 14″H x 25″ W x 2″ deep |
Temperature Drop: | 35 to 45⁰F |
Optional Heating: | 25kW electric |
Refrigeration: | 15 ton, R-410a, scroll compressor |
Lifting Options: | fork lift pockets in base |
Features
Targeted or “spot cooling” on problem areas or equipment
The Subcooled Air 2000 is at home in high-rise construction projects, as well as the tight space constraints found in shipyards, refineries and many industrial settings
Clumping powders and half-dry product are no longer an issue when cold, dry Subcooled Air is added to the normal air stream.
Warranty
Limited Warranty:
One year warranty on any defective parts.
Limitation of Liability:
To the extent allowable under applicable law, Subcooled Air’s liability for consequential and incidental damages is expressly disclaimed. Subcooled Air’s liability in all events is limited to and shall not exceed the cost of repair.